The x-ray diagnostic universal complex
The x-ray diagnostic universal complex KRD-50 "Indiascop-01"

The x-ray diagnostic universal complex KRD-50 "INDIascop-01"

     The x-ray diagnostic universal complex KRD-50  «INDIascop-01» is used for radiographic, fluoroscopic and tomography examinations in pediatrics, traumatology, myelography, gastroenterology, interventional radiology, urology and gynecology, digital angiography and endoscopy.

     Using of progressive technical and technological developments allows to achieve the high medical-technical characteristics in comparison with similar systems of world-wide producers:
    • diagnostic teleoperated tilting table with 3-in-1 solution for fluoroscopy,  tomography and radiography is supplied with digital image receptor for X-ray images receiving;
    • doctor- radiologist has possibility to make all kinds of examinations as distantly also from tableside keypad;
    • remote control  is realizes by using the ideology of «Full-operating console» and technology Touchscreen. It allows to operate the whole system working, parameters of exposition, to work with received digital X-ray images, to fill database.
    • the system is unique and doesn't have analogue in Ukraine.
    The excellent travel range of both the image receptor and tabletop enables coverage of intire body virtually without repositioning the patient.

General characteristics of tilting table:


TABLE - TOP

Tilting angles, degree...............................................±90
Dimensions of the table-top, cm................................40 x 75
Table-top height above the floor, cm...........................76
Lateral movement of the table-top, cm........................± 15

X-RAY TUBE
Type of anode ……………………………………..…......rotaing
Heat capacity, heat, unit...................................... ...300 000
Size of focal spot, mm.............................................0,6 x 1,2
Motorized rotation of the x-ray tube, degree ..............±180

COLUMN WITH X_RAY TUBE

Focal distance........................................................110-150 сm
Tilting angles during tomography...............................±40°
Angles of tomography..............................................8° 20° 30° 45?
Layer thickness.......................................................from 0 to 250 mm

 GENERATOR
Power requirements................................................ three-phase, 380 V, 50 Hz
Type...................................................................... high-frequency
Power.....................................................................50 (65) kW
Working frequency...................................................100 kHz
Radiography kV selection.........................................40-150 kV
Radiography mAs selection.......................................from 0,1 to 600
Exposure time..........................................................from 0,001 to 6 sec.